Tool / low-voltage DC

12V wire size calculator

For batteries, solar, RVs, boats, vehicles and LED lighting. Enter the current and one-way length; the calculator picks the smallest copper wire that keeps voltage drop within your limit.

12 V wire size calculator

A
System voltage
Max voltage drop

Estimate for planning only, based on NEC 2023. Local code and the inspector decide. Have a licensed electrician check mains work. How we calculate

12 V wire length chart

Longest one-way run in feet at 3% voltage drop on 12 V DC, copper. For 10% drop, multiply by 3.3. For 24 V at the same current, multiply by 2.

Wire5 A10 A20 A30 A50 A100 A
18 AWG4.62.31.2<1<1<1
16 AWG7.43.71.81.2<1<1
14 AWG125.92.921.2<1
12 AWG199.34.73.11.9<1
10 AWG30157.44.931.5
8 AWG4724127.94.72.4
6 AWG753719127.53.7
4 AWG119603020126
2 AWG189954732199.5
1/0 AWG30115175503015
2/0 AWG38019095633819
4/0 AWG6043021511016030
Resistance at 75 C. Check the wire's current rating as well: a long, light-load run can pass the drop test on wire that is too small for the current.

Sizing low-voltage DC wire

At 12 V, a 3% drop is only 0.36 V, so voltage drop, not heat, usually decides the size. A wire that would be fine on a 120 V circuit can be far too thin on the same current at 12 V.

Fuse every positive conductor as close to the battery as practical, and size the fuse to protect the wire. For boats, ABYC E-11 sets the rules for conductor sizing and overcurrent protection; for vehicles, follow the cable maker's ratings for the insulation type and bundle.

For 120 V and 240 V circuits, use the wire size calculator. For any wire and voltage, the voltage drop calculator shows the drop directly.

12V wire questions

What size wire for 12 V at 20 amps?

It depends on length. At 3% drop, 20 A on 12 V can run about 5 ft on 12 AWG, 7 ft on 10 AWG, 19 ft on 6 AWG and 47 ft on 2 AWG, one way. 12 V loses voltage fast, which is why low-voltage cables are thick.

Should I use 3% or 10% voltage drop?

Use 3% for anything where voltage matters: electronics, pumps, fridges, navigation and charging circuits. 10% is acceptable for basic lighting.

Is length one way or round trip?

Enter the one-way distance from the battery or source to the load. The calculator counts the return conductor for you.

Why does 24 V or 48 V allow thinner wire?

For the same power, doubling the voltage halves the current, and the allowed drop in volts doubles. Together that lets the same wire run four times as far.