Guide / cords and tools
Extension Cord Gauge Chart
For a 15 A load, use a 14 gauge cord up to about 75 ft, 12 gauge up to about 125 ft, and 10 gauge up to about 200 ft. A 16 gauge cord handles up to 13 A at 50 ft.
Chart rule: the cord's typical rating must cover the load, and voltage drop must stay at or under 5% at 120 V. Copper at 20 C. Always check the amp rating printed on the cord.
Minimum extension cord gauge by amps and length
| Load | 25 ft | 50 ft | 100 ft | 150 ft |
|---|---|---|---|---|
| 5 A | 16 AWG | 16 AWG | 16 AWG | 14 AWG |
| 10 A | 16 AWG | 16 AWG | 14 AWG | 12 AWG |
| 13 A | 16 AWG | 16 AWG | 12 AWG | 10 AWG |
| 15 A | 14 AWG | 14 AWG | 12 AWG | 10 AWG |
Voltage drop by cord gauge at 15 A
| Cord | 25 ft | 50 ft | 100 ft | 150 ft |
|---|---|---|---|---|
| 16 AWG | 2.5% | 5% | 10% | 15.1% |
| 14 AWG | 1.6% | 3.2% | 6.3% | 9.5% |
| 12 AWG | 1% | 2% | 4% | 6% |
| 10 AWG | 0.6% | 1.2% | 2.5% | 3.7% |
Common loads
- Lamps, phone chargers, fans: under 2 A. Any cord works.
- Drills, sanders, jigsaws: 3 to 7 A. 16 gauge up to 50 ft.
- Circular saws, shop vacs, leaf blowers: 10 to 15 A. 14 or 12 gauge.
- Pressure washers, table saws, air compressors: 13 to 15 A. 12 gauge, or 10 gauge on long runs.
The nameplate amps on the tool are the number to use. If only watts are listed, divide by 120 to get amps.
For the numbers behind a specific cord, see the 14 gauge, 12 gauge and 10 gauge pages, or run your own length in the voltage drop calculator.
Safety: do not run cords under rugs or through doorways where they get pinched, do not chain cords together, and fully uncoil a reel under heavy load. A warm cord is a sign it is too small for the load.
Extension cord questions
What gauge extension cord for 15 amps?
A 14 gauge cord for runs up to about 75 ft, 12 gauge up to about 125 ft, and 10 gauge up to about 200 ft. Check the cord is marked for 15 A.
Is a 16 gauge extension cord OK for a space heater?
No. Space heaters draw 12.5 A or more for long periods, and most manufacturers say to plug them straight into the wall. If you must use a cord, use a heavy-duty 12 or 14 gauge cord rated 15 A and keep it short and uncoiled.
Why does a long cord make tools weaker?
Voltage drop. A long, thin cord loses several volts under load, so motors draw more current, run hotter and lose power. Pick the gauge from the chart to keep the drop at 5% or less.
What do the numbers on an extension cord mean?
A marking like 14/3 means 14 gauge conductors and 3 conductors (hot, neutral and ground). Letters like SJTW describe the jacket: S service, J junior (300 V), T thermoplastic, W outdoor rated.